Ravel 4 Zone Fire Alarm system

Ravel 4 Zone Fire Alarm system

Ravel 4 Zone Fire Alarm system

  • Product Code : Ravel 4 Zone Fire Alarm system
  • Availability : In Stock
  • ₹ 12,990.00

  • Ex Tax :₹ 12,990.00

Product Overview

RE-104 is a right blend of affordable design and quality with latest technology for fire alarm control panels. This microprocessor based conventional Fire Alarm Control panel, is designed for small size commercial buildings and small scale industries. RE-104 model is an user friendly 4 zone standalone control panel, with optional zone wise Sounder/Contact respectively.

Special Features

  • Switched Mode Power Supply.
  • Modular Construction, Serviceable.
  • Surface Mount Technology.
  • Battery polarity & deep discharge protection.

Features

  • As per IS -15908: 2011 Standard.
  • 16 X 2 Dot Matrix LCD Display.
  • Standby battery backup with built in charging.
  • Fire / Fault status in unambiguous colored LED indication.
  • Switch Mode Power Supply.
  • Tactile Keypad for easy panel operation.
  • System ON indication.
  • Main, Standby status indication.
  • Low Battery visual warning with audible tone.
  • Relay output for actuators, for Fire and Fault.
  • Lamp Test facility
  • Zone wise one man Walk Test Facility.
  • Zone wise Isolation facility with loop voltage cut off.
  • Compatible to all type of Conventional Detectors.
  • Optional Zone Wise Sounder / Zone Wise Contact.

Electrical Specification

Primary Power

  120 / 220VAC + 10% -15%, 60 / 50 Hz. 60W

Standby Power

    24VDC (2 Nos of 12V, 7Ah Sealed Lead acid battery).

    Quiescent current : 55mA

Operating Condition

   Operating Temperature - 0 - 49° C/32-120° F.

    Storage Temperature - 0 to 60 C

    Relative Humidity - 93 ± 2% RH (non- condensing) at 32 ±2° C/90 ±3° F.

Charging Circuit

        Charging Voltage 28.0V, ± 2%

        Charging Current 0.5 A (Max.).

Notification Appliance Circuits

    Class B wiring

    Operating Nominal Voltage: 24VDC

    Current for NACs : 0.6 Amp

    End-Of-Line Resistor : 4K7, 1/4 watt

Common Relays

Type

Form C

No of Relays

3

Relay Contact Rating

2Amps @ 30 VDC, 0.5Amps @125VAC.

Power Factor

1.0

Initiating Device Circuits (Zone Circuit)

All zones are Class B wiring Normal Operating Voltage

14- 21 VDC

Alarm Current

 15 - 30 mA

Short Circuit Current

42 mA Maximum

Loop resistance

50 ohms Maximum

End-Of-Line Resistor

4.7 K, 1/4 watt

Standby Current

 6.8 mA (2.4 mA for Detectors)


Mounting Details    

             

Mechanical Specification

Dimensions

(350W X 250H X 100D)

Color 

Red / White

Construction

18 Gauge (1.22mm) CRCA sheet with powder-coated Finish

IP Rating 

 IP50

Cable Entry

11xø19mm Knockout in top of the cabinet


Wiring Diagram


Ordering Information:

MODEL

DESCRIPTION

RE-104-W
4 ZONE Fire Alarm Panel
RE-104-R
4 ZONE Fire Alarm Panel

Compatible Devices

MODEL

DESCRIPTION

RE-316S-2L
Photoelectric Smoke detector with base.
RE-316H-2L
Heat detector with base.
RE-316SH-2L
Photoelectric & Heat detector with base
RE-716 MR
Conventional Manual Call Point.
RE- 24 CS
Conventional Sounder.


Write a review